GGU-2D-SSFLOW: "Discharges" menu item

GGU-2D-SSFLOW: "Discharges" menu item

The FEM mesh will be displayed at the nodes, together with the calculated discharge. Discharges other than zero are present at the nodes at which you have defined a water level boundary condition or a source boundary condition. At all other nodes the discharge equals zero (continuity condition). Using the dialog box you can specify the type of presentation.

image-20241028-083800.png

After using "OK" to exit the dialog box you define the area for which the discharge is to be calculated by clicking four point in an anti-clockwise direction. The calculated values are first displayed in a message box and then as a circle chart in your graphics.

If you are investigating a horizontal-plane system with a leaky aquifer, you may also calculate the discharge for the blanket only by activating the additional "Discharge through blanket" check box.

 